Commands Listed in Alphabetical Order
Arguments
<QString> is a q
uoted string that represents the frame ID portion of the binary
header string.
Examples
TR
IGGER:A:BUS:B1:FLEXRAY:HEADER:FRAMEID “11001100101”
sets the
frame ID portion of the binary header string to 11001100101.
T
RIGGER:A:BUS:B1:FLEXRAY:HEADER:FRAMEID?
might return
TRIGGER:A:BUS:B1:FLEXRAY:HEADER:FRAMEI D "XXXXXXXXXXX"
indicating the frame ID portion of the binary header string is “don't care”.
TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits
This command specifies the indicator bits portion of the binary header string when
triggering on the FlexRay bus header. The trigger condition needs to be set to
HEADer (using TRIGger:A:BUS:B<x>:FLEXray:CONDition).
B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDB its <QString>
TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDB its?
Arguments
<QString> is a quoted string that is the indicator bits portion of the binary
header string.
Examples
TRIGGER:A:BUS:B1:FLEXRAY:HEADER:INDBIT S “11001” sets the indicator
bits portion of the header string to 11001.
TRIGGER:A:BUS:B1:FLEXRAY:HEADER:INDBIT S? might return
TRIGGER:A:BUS:B1:FLEXRAY:HEADER:INDBIT S "XXXXX" indicating that
the indicator bits portion of the header string are “don't cares”.
TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength
This command specifies the payload length portion of the binary header string
when triggering on the FlexRay bus header. The trigger condition needs to beset
to HEADer (using TRIGger:A:BUS:B<x>:FLEXray:CONDition).
B<x>
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-821