Rear--Panel Connectors
4
SPG600 & SPG300 Sync Pulse G enerators Quick Reference Manual
The sync pulse generator operates from an AC line frequency of 48 to 63 Hz,
over the range of 85 to 250VAC, without the need for configuration. Refer to the
SPG600 & SPG300 Sync Pulse Generators User Manual for additional
information on power and environment requirements.
Connects this port to connect to your local Ethernet network. You can control the
sync pulse generator remotely through the port. You can also upload and
download signal files, logo files and preset files through the port.
A 9-pin subminiature D-type connector used as a ground closure interface for
recalling one of the seven preset, outputting an alarm signal, and displaying an
alarm status on the LCD.
Loopthrough connectors for an external reference signal. These inputs accept the
NTSC/PAL black burst signals and CW signals. Be sure to install a 75
termination on the unused connector.
Analog black or analog test signal outputs. By default, the C H1, CH2, and CH3
connectors output black burst signals, and the CH4 connector outputs an analog
test signal. Use the System menu to change the output configuration.
Analog black or analog test signal outputs (SPG600 Option 02 only). By default,
the CH5, CH6, and CH7 connectors output black burst signals, and the CH8
connector outputs an analog test signal. Use the System menu to change the
output configuration.
Serial digital black or serial digital test signal outputs. By default, the SDI 1
connec tor outputs a seria l digital black signal, and the SDI 2 connec tor outputs a
seria l digital test signal. Use the System menu to change the output configura tion.
Serial digital black or serial digital test signal outputs (SPG600 Option 03 only).
By default, the S DI 3 connector outputs a serial digital black signal, and the SDI
4 connector outputs a serial digital test signal. Use the System menu to change
the output configuration.
AES/EBU serial digital audio outputs for channels 1 & 2, 3 & 4, 5 & 6, and 7 &
8 respectively (SPG600 only).
AES/EBU s erial digital audio or analog audio outputs for channels 1 & 2 and
3&4 respectively. By default, these connectors output an AES/EBS serial digital
audio. Use the S ystem menu to change the output configuration.
48 kHz word clock signal output.
100 BASE-T
GPI (General Purpose
Interface)
REF
CH1, CH2, CH3, and CH4
CH5, CH6, CH7, and CH8
SDI 1 and SDI 2
SDI 3 and SDI 4
AES 1+2, AES 3+4,
AES 5+6, and AES 7+8
1+2/RIGHT and 3+4/LEFT
(XLR connector)
WORD CLK

Other manuals for Tektronix SPG3UP 01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix SPG3UP 01 and is the answer not in the manual?

Tektronix SPG3UP 01 Specifications

General IconGeneral
BrandTektronix
ModelSPG3UP 01
CategoryPulse Generator
LanguageEnglish

Related product manuals