Rackmounting the Instrument (SP G600 Only)
28
SPG600 & SPG300 Sync Pulse G enerators Quick Reference Manual
Installation Instructions
This procedure describes how to assemble and install the slide-out tracks in the
equipment rack, and then how to install the instrument into the rack.
1. Identify the equipment rack right verses left slide-out track assemblies by
finding the date code label on each assembly. The equipment rack left-side
assembly has a date code that ends with “LH”, for left hand. The equipment
rack right-side assembly has a date code ending with “RH”.
2. Measure the distance between the front and rear rail of the equipment rack.
3. Align the rear bracket to the right slide-out track as shown in Figure 28. Note
that the rear bracket has multiple pairs of mount-through holes. When
aligning the bracket and track, be sure to select a pair of holes that mount the
rear bracket so that the flange-to-flange distance matches the front-rail to rear
rail spacing of the rackmount rack just measured in step 2.
4. Using a screwdriver with a number two Pozidriv tip, secure the rear bracket
to the right slide-out track using two 10-32 screws and a bar nut. Leave the
screws loose so that you can adjust the overall length of the slide-out track
assembly in the rack.
5. Repeat steps 3 and 4 to assemble the left slide-out track assembly.
Assembling the Slide-out
Tracks