Command Descriptions
2- 152
TDS200, TDS1000/2000, TDS1000B/2000B, TPS2000 Programmer
MATH:FFT:HORizontal:SCAle <NR3>
MATH:FFT:HORizontal:SCAle?
<NR3> specifies the horizontal magnification factor, where the axis of
magnification is the center vertical graticule line. Valid zoom factors
are 1, 2, 5, and 10. If other values are entered the oscilloscope
rounds the value of <NR3> to the neare st valid zoom factor.
MATH:FFT:HORizontal:SCAle 5
Sets the FFT waveform horizontal zoom factor to X5.
MATH:FFT:HORizontal:SCAle?
Might return 2.0E0, indicating that the zoom factor setting is X2.
MATH:FFT:VERtical:POSition
NOTE. You can use t his command with a TDS1000, TDS2000,
TDS1000B, TDS2000B, and TPS2000 oscilloscope, as well as a
TDS200 oscilloscope with a TDS2MM measurement module.
Sets or queries the FFT math waveform vertical position.
Math
MATH:FFT:VERtical:POSition <NR3>
MATH:FFT:VERtical:POSition?
<NR3> specifies the FFT waveform vertical position in divisions.
Syntax
Arguments
Examples
Group
Syntax
Arguments

Table of Contents