Command Descriptions
2- 148
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
HORizontal:SCAle
Sets the time per division for the main time base and is identical to the HORi-
zontal:MAIn:SCAle command. It is provided to maintain program compatibility
with some older models of Tektronix oscilloscopes.
Horizontal
HORizontal:SCAle <NR3>
HORizontal:SCAle?
HORizontal:SECdiv
Sets the time per division for the main time base and is identical to the HORi-
zontal:MAIn:SCAle command. It is included here for compatibility purposes.
Horizontal
HORizontal:SECdiv <NR3>
HORizontal:SECdiv?
HORizontal:TRIGger:POSition
Sets or returns the position of the trigger. This is only applied when delay mode
is off.
Horizontal
HORizontal:TRIGger:POSition <NR1>
HORizontal:TRIGger:POSition?
<NR1> is from 0 to 100 % and is the amount of pretrigger information in the
waveform.
HORIZONTAL:TRIGGER:POSITION?
might return :HORIZONTAL:TRIGGER:POSITION 50.