Command Descriptions
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
2- 289
<NR3> is a floating point value with exponent that sets the pulse width trigger
time value. This argument has a range of 39.6E--9 (39.6 ns) to 10.0E0 (10 s), in
increments of 13.2 ns. Values that are not an increment of 13.2 ns are rounded to
the nearest correct value.
TRIGGER:A:PULSE:WIDTH:WIDTH?
might return TRIGGER:A:PULSE:WIDTH:WHEN MORETHAN;WIDTH 0.0000011880.
TRIGger:A:SETLevel (Set Only)
Sets the trigger level to 50%. This is equivalent to pressing the front-panel SET
TO 50% button.
Trigger
TRIGger:A:SETLevel
TRIGGER:A:SETLEVEL
sets the trigger level midway between MAX and MIN.
TRIGger:A:TYPe
Sets or queries the type of A trigger. This is equivalent to setting Type in the
Trigger menu.
Trigger
TRIGger:A:TYPe { EDGe | VIDeo | COMMunication | LOGIc | PULse }
TRIGger:A:TYPe?