Monitoring the SDI Physical Layer
10. Use the General
knob to increase or decrease the cable length setting. The
maximum length you can enter is 300 meters; the minimum length is 0 meters.
11. Select Eye Amp
litude Max . Use the General knob to increase or decrease
the setting. The maximum amplitude you can enter is 1010 mV; the minimum
amplitude is 700 mV.
12. Select Eye Amplitude M in. Use the General knob to increase or decrease the
setting. The maximum amplitude you can enter is 10 mV below the current
Eye Amplitude Max setting; the minimum amplitude is 530 mV.
13. Select Eye Risetime Max. Use the General knob to increase or decrease the
setting. The rise time range for SD is 410 ps to 3000 ps. The rise time range
for HD and 3G is 10 ps to 1000 ps.
14. Select Eye Risetime Min. Use the General knob to increase or decrease the
setting.
15. Select Eye Falltime Max. Use the General knob to increase or decrease the
setting. The fall time range for SD is 410 ps to 3000 ps. The fall time range
for HD and 3G is 10 ps to 1000 ps.
16. Select Eye Falltime Min. Use the General knob to increase or decrease the
setting.
17. Select Eye Rise-Fall Delta. Use the General knob to increase or decrease the
setting. The maximum value you can enter is 1000 ps; the minimum value
is 0 p
s.
To Congure Physical Layer Alarms
NOTE. You can read more about alarms in the Alarms section. (See page 113,
Alarms.)
1. From the CONFIG menu, select Alarms > Physical Layer.
2. Press the SEL button.
3. UsethearrowkeysandtheSEL button to mark the squares for the alarms
you want to monitor.