ARIB Displays
ARIB Displays
Your instrument supports conformance to ARIB data standards contained in the
signal source. You will need to enable the ARIB displays from the Configuration
menu in the Au
x Data Settings submenu. ARIB information is contained in the
following status screen displays:
ARIB Status
ARIB STD-B.39 Display
ARIB STD-B.37 Display
ARIB STD-B.35 Display
ARIB TR-B.23 (1) Display
ARIB TR-B.23 (2) Display
ARIB TR-
B.22 Display
The following DID and SDID values are defined for common types of
ARIB-compliant data.
DID and SDID values for common ARIB data types
Ancillary data type
DID
value
SDID
value
ARIB TR-B.22, Sub Information of transmitting materials
0x5F 0xE0
ARIB TR-B.23, Line 20 User Data - 1 0x5F
0xFC
ARIB TR-B.23, Line 20 User Data - 2 0x5F 0xFB
ARIB STD-B.35 Trigger Signal for Data Broadcasting
0x5F 0xFD
ARIB STD-B.37 Closed Captioning
Analog signal
SD signal
HD signal
0x5F
0x5F
0x5F
0xDD
0xDE
0xDF
ARIB STD-B.39 Inter Stationary Control Data
ARIB specification
ITU specification
0x5F
0x43
0xFE
0x01