Display Information
Arrowhead show
s Gamut violations of the SDI input if translated to the
Composite domain.
Spearhead sho
ws lightness, color value, a nd saturation of the RGB color
space of all video signals, including dual link signals.
To turn on th
e Multi-Input display mode, select Multi-Input Display and press
SEL. Next, press the FULL button to view the display in Multi-Input mode.
NOTE. The M ulti-Input menu option is only available in the GAMUT pop-up
menu when the feature is enabled from the MAIN button or CONFIG button menu.
(See page 27, Multi-Input Display Mode.)
Timing Display
Pressin
gtheMEAS button displays a Tektronix proprietary display that simplifies
measuring the timing difference between two signals as the timing is corrected.
Using the Timing display enables you to easily compare and correct the timing
between two signals. (See Figure 22.)
Figure 2 2: Timing display
Elements of the Timing
Display
Input Signal Indicator: A single circle representing timing of input signal
relative to the reference.
1
Reference Indicator: A cross-hair indictor centeredinthedisplayrepresents
the reference signal.
WFM8200 and WFM8300 Waveform Monitors 43