EasyManua.ls Logo

Tektronix WFM8200 - Monitoring for Safe Area Compliance

Tektronix WFM8200
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Closed Captioning (CC), Teletext, AFD, and Safe Area Compliance
Usage Notes
PICT displays i
n individual tiles allow their Services and Pages to be selected
independently.
CC text is not c
aptured with the Picture image when using Freeze.
CC/Teletext setups are also stored when saved with Presets and restored at
power on.
The CC alarms are available from the CongurationmenuintheAlarms
submenu und
er Closed Captions/Metadata.
Teletext can be v iewed as captions or as a whole page.
Monitoring for Safe Area Com pliance
To display graticules for m onitoring for incorrect placements of nonessential
element
s relative to essential ones, set global settings in the Conguration menu
and turn on up to four Safe Area graticules, each with independent settings, in
the Picture menu.
To Con gureSafeArea
Graticules
Before
using Safe Area Graticules, congure them from the Conguration menu
by performing the following steps:
1. Selec
t Graticules and then select Safe Area Graticule Standard from the
CONFIG menu.
2. Choose from the SMPTE, ITU,orARIB TR-B.4 standards. The selection
you choose w ill be the graticule used when AUTO is chosen for any of the
four Safe Area Graticules, acces sed in the Picture menu.
3. To set the Height, Width, and Offsets of the title and action areas for Custom
Safe Graticules 1 and 2, rst select the title or action to change.
4. Set the percentage level for each of the parameters. Parameters are set as a
percentage of screen h eight or width, and you can watch the graticules update
o
n the screen as you change them.
NOTE. The custom parameters you set are used when Custom_1 or Custom_2 is
chosen for any of the four S afe Area Graticules accessed in the Picture menu.
To Display Safe Area
Graticules
1. Select a tile.
2. Press and hold the PICT button to display the Picture menu.
3. Select Safe Area Action 1.
162 WFM8200 and WFM8300 Waveform Monitors

Table of Contents

Related product manuals