Monitoring the SDI Physical Layer
4. Press the CURSO
R button to display the measurement cursors.
5. Position the rst timing cursor at the left edge of the zero-crossing point of
the Eye wavefo
rm. (See Figure 56.)
NOTE. If necessary, use the Gain and Sweep controls for better vertical and
horizontal resolution. (See page 89, Gain, Sweep, and Magnication.)
6. Position the second timing cursor at the right edge of the zero-crossing point
of the Eye waveform. (See Figure 56.)
7. Check that the Delta readout is less than the following: (See Figure 56.)
SD Signal
s (per SMPTE 259M)
Timing jitter (10 Hz lter): 740 ps (0.2 unit intervals).
Alignment jitter (1 kHz lter): 740 ps (0.2 unit intervals).
HD Signals (per SMPTE 292M)
Timing jitter (10 Hz lter): 67 3 ps (1.0 unit intervals).
Alignment jitter (100 kHz lter): 134 ps (0.2 unit intervals).
3Gb/s
Signals (per SMPTE 425M)
Timing jitter (10 Hz lter): 33 6 ps (1.0 unit intervals).
Alignment jitter (100 kHz lter): 67 ps (0.2 unit intervals).
WFM8200 and WFM8300 Waveform Monitors 111