Audio Monitoring
Table 6: Channel modes versus Listening modes (cont.)
Channel mode Listening mode Main channel output function
EX
Default to Full mode
Full
All 2/1 channels
3 Stereo S mixed into L and R with smix coefcient
Phantom
Default to Full mode
Stereo Lo/Ro downmix
Mono Lo+Ro
PL Full
LCRS from Lt/Rt downmix
PL 3 Stereo 3 Stereo from Lt/Rt
2/1
PL Phantom
Phantom from Lt/Rt
EX
Default to 3 Stereo m ode
Full
Default to 3 Stereo m ode
3 Stereo All 3/0 channels
Phantom
C mixed into L and R with cmix coefcient
Stereo Lo/Ro downmix
Mono Lo+Ro
PL Full
LCRS from Lt/Rt downmix
PL 3 Stereo 3 Stereo from Lt/Rt
3/0
PL Phantom
Phantom from Lt/Rt
EX
Default to Stereo m ode
Full
Default to Stereo m ode
3 Stereo Default to Stereo mode
Phantom
Default to Stereo m ode
Stereo 2/0 channels
Mono L+R
PL Full
LCRS from 2/0 c hannels
PL 3 Stereo 3 Stereo from 2/0 channels
2/0
PL Phantom
Phantom from 2/0 channels
EX
Default to Mono mode
Full
Default to Mono mode
3 Stereo Default to Mono mode
Phantom
Default to Mono mode
Stereo Default to Mono mode
Mono Mono center channel output
PL Full
Default to Mono mode
PL 3 Stereo Default to Mono mode
1/0
PL Phantom
Default to Mono mode
WFM8200 and WFM8300 Waveform Monitors 157