EasyManua.ls Logo

Tektronix WFM8200 - Page 77

Tektronix WFM8200
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Display Information
The Error Log is
also divided into the following four columns:
Source: Shows the inputs on which the errors have occurred.
Error Status: Shows the current state of the entry: White items are
informational and identify a change in instrument state; Green items are
errors that
have cleared; Red items are triggered errors.
Timecode: Shows the time, according to VITC or LTC in the signal, that the
error occur
red. In the case of ongoing errors, this shows the time the error
rst occurred.
Time: Show
s the time, according to the internal clock, that the error occurred.
Error Log pop-up menu.
Mute Ala
rms: Mutes alarms for all Status display types.
Logging Active: Turns alarm error logging On or Off.
Logging Reset: Press the SEL button to clear the log.
Input/Channel: Allows you to select to lter errors in the error log so that
you can view them by channel or input. W hen the instrument is in SIM
mode, you can select to view errors from only Channel 1 (the left channel) or
Chann
el 2 (the right channel).
Save to USB (ALL): Saves the entire unltered error log to a USB memory
devi
ce.
Save to USB (Sel.): Saves only the errors in the error log for the selected
cha
nnel or input to a USB memory device.
WFM8200 and WFM8300 Waveform Monitors 61