Display Information
Source Level:S
hows the calculated launch amplitude of the signal source,
assuming a continuous run of cable of the specied type, as specied in the
Launch Amplitude elds of the Physical Layer Settings selection available
from the CONFIG button.
Cable Type: Shows the cable type used to connect the signal source to the
instrument, as specied in the Cable Type eld of the Physical Layer Settings
selection available from the CONFIG button.
Eye Amplitude: Shows the amplitude of the eye waveform. (Requires
Option PHY.)
Eye Risetime: Shows the rise time of the eye waveform. (Requires Option
PHY.)
Eye Falltime: Shows the fall time of the eye waveform. (Requires Option
PHY.)
Eye Rise-Fall: Shows the delta between rise time and fall time of the eye
waveform. (Requires Option PHY.)
EyeRiseOvershoot: Shows the percentage of rise time overshoot of the eye
waveform. (Requires Option PHY.)
Eye Fall Overshoot: Shows the percentage of fall time overshoot of the e ye
waveform. (Requires Option PHY.)
SDI S
tatus display pop-up menu.
Mute Alarms: Mutes alarms for all Status display types.
Jitter1 HP Filter: Selec t the lter type: Timing, Align, 10 Hz, 100 Hz,
1 kHz, 10 kHz, 100 kHz.
Jitter2 HP Filter: Selec t the lter type: Timing, Align, 10 Hz, 100 Hz,
1 kHz, 10 kHz, 100 kHz.
WFM8200 and WFM8300 Waveform Monitors 79