Code Parameter Conrmation
70
Silent connection and call answering:
Default setting: 0
0 = enabled
1 = disabled
Use this configuration step to determine when the speaker will be
activated during calls from the device. In case silent connection
is enabled, the signals indicating a connected call, a busy line or
error messages will not be played via the speaker. Disabling the
silent connection option will result in the speaker being activated
upon device activation.
In case silent connection is enabled, the device will wait for the
called party to pick up before a communication channel is opened.
#
#
73
Label illumination: Default setting: 1
0 = disabled
1 = enabled
Use this step to turn label illumination on/off. Requires an
additional 15 V power supply.
#
#
900
Advanced configurations: Default setting: 0
0 = disabled
1 = enabled
The following configuration may only be adjusted with enabled
extended configuration.
#
#
9910
Timeout for call answering: Default setting: 60
0 = connection interval
1 = 1 second
:
250 = 250 seconds
Use this configuration step to set the amount of time the device
waits for a call to be picked up according to configuration step 58
or the special symbol *8xx respectively.
#
#
:
#
945
Debounce time: Default setting: 1
Debounce time buttons 1-3, alarm button
0 = 0 ms
1 = 128 ms
2 = 256 ms
:
9 = 1152 ms
This configuration step will set the debounce time for all keys (i.e.
the amount of time a key needs to be pressed before it will be
recognised as an active key).
#
#
#
:
#
Configuration and Set-up
55www.behnke-online.com
GB
Instructions for Series 5 / 10