CA60Plus control panel Installation manual 15
ADDRESSES 02..16 USER CODE 2..16 ATTRIBUTES
The programming is the same as for Address 01.
DEFAULT : codes 02 to 16 have been assigned the attributes Disarm, Full ARM, Stay ARM, Force ARM,
LOG, BYPASS. However, no code combination has been introduced
0. User codes in the CA60Plus control panel
ADDRESS 00 MANAGER ACCESS TO USER CODE ATTRIBUTES
NO Manager access to user code authority is denied.
Light-emitting diodes 1 to 6 do not light up.
YES Manager access to user code authority is granted.
Light-emitting diodes 1 to 6 light up.
DEFAULT : YES
ADDRESS 01 USER CODE 1 ATTRIBUTES
USER CODE 1 attributes are assigned at this address. The user code can have
more than one attribute. Pressing a digital button with the respective number
activates the given attribute. The light-emitting diode with the number of the
pressed digit will light up to indicate the selection. Pressing the same digit again
will inactivate it and the light-emitting diode with the number of the pressed digit
will go out.
Only those light-emitting diodes, which correspond to the assigned attributes, will
remain lit at the end of the procedure. Pressing the ENTER button confirms the pro-
grammed attributes.
1 Disarm Authorizes this user code to Disarm the site.
2 Full ARM Authorizes this user code to Full ARM the site.
3 Stay ARM Authorizes this user code to arm those zones that have not been assigned a
STAY attribute.
4 Force ARM Authorizes this user code to arm with open zones for which a FORCE attribute
has been assigned.
5 Log Authorizes this user code to access log events.
6 Bypass Authorizes this user code to bypass zones in armed site.
DEFAULT : Disarm, Full ARM, Stay ARM, Force ARM, LOG, BYPASS