24 CA60Plus control panel Installation manual
5. Engineer parameters
ADDRESS 53 RESTORING DEFAULT MANAGER CODE (PARTIAL
SOFTWARE RESET)
DEFAULT Restoration of the default manager code. Buttons 1, 2, 3, 4, 5, 6 are pressed in
MANAGER succession and confirmed with the ENTER button.
CODE The station restores the default 0000 manager user code.
ADDRESS 50 ENGINEER CODE CHANGE
ENGINEER CODE A new access code to the alarm station engineer parameters can be assigned at
this address. The light-emitting diodes 3, 4, 5 and 6 on the keypad display light
up. These go out one by one as the new code is entered. The new code has to
be entered a second time.
DEFAULT : 7777
ADDRESS 51 BLOCKING THE HARDWARE RESET
Disables or enables the hardware RESET of the alarm station. Specialized
service is required where the hardware RESET is disabled and the en-
gineer code is obscure.
NO Hardware RESET is disabled.
Light-emitting diodes 1 to 6 do not light up.
YES Hardware RESET is enabled.
Light-emitting diodes 1 to 6 light up.
DEFAULT : YES
ADDRESS 52 RESTORING DEFAULT PARAMETERS (SOFTWARE RESET)
DEFAULT Restoration of default settings of the station. The buttons 1, 2, 3, 4, 5, 6 are
SETTINGS pressed in succession and confirmed with the ENTER button.
ADDRESS 54 AUTHORITY TO ARM USING A ONE PUSH-BUTTON (QUICK
ARM)
QUICK NO Arming disabled without legal user code.
ARM Light-emitting diodes 1 to 6 do not light up.
ENABLE YES Arming enabled without legal user code.
Light-emitting diodes 1 to 6 light up.
DEFAULT : YES
ADDRESS 55 AUTHORITY CODE DURING AMBUSH (AMBUSH CODE)
ENABLE NO Disabled ambush code.
AMBUSH Light-emitting diodes 1 to 6 do not light up.
CODE YES Enabled ambush code. The code is made up by adding 1 to a legal user
code. There is no carrying over for codes ending in the figure 9. For example,
the ambush code for 1234 is 1235, and for 9999 it is 9990.
Light-emitting diodes 1 to 6 light up.
DEFAULT : YES