CA60Plus control panel Installation manual 39
Coding recordings in log events
Log events can be viewed at Ad-
dress 94 of the engineer program-
ming.
In order to view a previous event
press the T button. In order to
view a next event press the S but-
ton. To view additional informa-
tion (xx is the user code or event
zone number) press ENTER. Sin-
gle click the ENTER button to re-
turn to the list of events.
Recorded events can be viewed
with the help of the table, which
shows message coding within the
system and LED keypad indica-
tion. All possible combinations of
keypad light-emitting diodes, the
meaning of each combination and
the decoding of the specifying re-
cording xx for the number of the
user code or zone, are shown for
ease in reading log event record-
ings.
Supplement C Additional information
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
Burglary Alarm type event in xx zone
Burglary Alarm type restoring event in xx zone
Fire type alarm event in xx zone
Fire type restoring event in xx zone
Panic type alarm event in xx zone
Panic type restoring event in xx zone
Tamper type alarm event in xx zone
Tamper type restoring event in xx zone
Medical type alarm event in xx zone
Medical type restoring event in xx zone
Burglary Alarm type xx zone bypass
Burglary Alarm type xx zone bypass restoring
Fire type xx zone bypass
Fire type xx zone bypass restoring
Panic type xx zone bypass
Panic type xx zone bypass restoring
Tamper type xx zone bypass
Tamper type xx zone bypass restoring
Medical type xx zone bypass
Medical type xx zone bypass restoring
Disarm by xx user
Remote disarming by xx user
Disarming by key-switch in xx zone
Arming by xx user
Remote arming by xx user
Arming by key-switch in xx zone
Quick arm type arming
Program mode entry
Program mode exit
Introducing ambush code by xx user
Telephone line failure
Recovery of faulty telephone line
Unsuccessful communication
Periodic test message communication
Digital communicator manual test
Fuse blown
Restored fuse
System default RESET
Loss of 220 V AC power supply
Restored 220 V AC power supply
Low battery charge level
Restored battery charge level
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16