36 CA60Plus control panel Installation manual
Supplement B Default programming table
PROGRAM MENU ADDRESS LED 1 LED 2 LED 3 LED 4 LED 5 LED 6
MA NGER A CCESS 00 NO - LED1 to LED6 do not light Y ES - LED1 to LED6 light
USER CODE 1 01 DISARM FULL ARM STAY ARM FORCE ARM LOG BYPASS
USER CODE 2 02 DISARM FULL ARM STAY ARM FORCE ARM LOG BYPASS
USER CODE 3 03 DISARM FULL ARM STAY ARM FORCE ARM LOG BYPASS
USER CODE 4 04 DISARM FULL ARM STAY ARM FORCE ARM LOG BYPASS
USER CODE 5 05 DISARM FULL ARM STAY ARM FORCE ARM LOG BYPASS
USER CODE 6 06 DISARM FULL ARM STAY ARM FORCE ARM LOG BYPASS
USER CODE 7 07 DISARM FULL ARM STAY ARM FORCE ARM LOG BYPASS
USER CODE 8 08 DISARM FULL ARM STAY ARM FORCE ARM LOG BYPASS
USER CODE 9 09 DISARM FULL ARM STAY ARM FORCE ARM LOG BYPASS
USER CODE 10 10 DISA RM FULL A RM STA Y A RM FORCE A RM LOG BY PA SS
USER CODE 11 11 DISA RM FULL A RM STA Y A RM FORCE A RM LOG BY PA SS
USER CODE 12 12 DISA RM FULL A RM STA Y A RM FORCE A RM LOG BY PA SS
USER CODE 13 13 DISA RM FULL A RM STA Y A RM FORCE A RM LOG BY PA SS
USER CODE 14 14 DISA RM FULL A RM STA Y A RM FORCE A RM LOG BY PA SS
USER CODE 15 15 DISA RM FULL A RM STA Y A RM FORCE A RM LOG BY PA SS
USER CODE 16 16 DISA RM FULL A RM STA Y A RM FORCE A RM LOG BY PA SS
LOOP TYPE 20 ALARM - LED1 to LED6 light
ZONE 1 TYPE
21
A TTRIBUTS ZONE 1 AUTOBYPASS BYPASS STAY FORCE DOUBLE CHIME
ZONE 2 TYPE
22
A TTRIBUTS ZONE 2 AUTOBYPASS BYPASS STAY FORCE DOUBLE CHIME
ZONE 3 TYPE
23
A TTRIBUTS ZONE 3 AUTOBYPASS BYPASS STAY FORCE DOUBLE CHIME
ZONE 4 TYPE
24
A TTRIBUTS ZONE 4 AUTOBYPASS BYPASS STAY FORCE DOUBLE CHIME
ZONE 5 TYPE
25
A TTRIBUTS ZONE 5 AUTOBYPASS BYPASS STAY FORCE DOUBLE CHIME
ZONE 6 TYPE
26
A TTRIBUTS ZONE 6 AUTOBYPASS BYPASS STAY FORCE DOUBLE CHIME
AUTOBYPASS COUNT 27
PULSE COUNT 28
ENABLE INSTANT 29 NO - LED1 to LED6 do not light YES - LED1 to LED6 light
PGM 1
31
ALARM PANIC TAMPER FIRE FIRE/RST ON/OFF
MEDICAL PS/bypass AC LOSS BAT LOW FUSE/NO TEL Pol+ / -
PGM 2
32
ALARM PANIC TAMPER FIRE FIRE/RST ON/OFF
MEDICAL PS/bypass AC LOSS BAT LOW FUSE/NO TEL Pol+ / -
PGM 3
33
ALARM PANIC TAMPER FIRE FIRE/RST ON/OFF
MEDICAL PS/bypass AC LOSS BAT LOW FUSE/NO TEL Pol+ / -
SIREN OUTPUT 34 A LA RM PA NIC TA MPER FIRE/A LW ON SQUA WK OFF SQUA WK
EXIT TIME 40
ENTRY TIME 41
BELL TIME 42
BELL DELAY 43
SET CLOCK 44
SET DATE 45
LF DELAY
46
A C DELA Y 30min 47 NO - LED1 to LED6 do not light Y ES - LED1 to LED6 light
FIRE DURA TION 48
Until a valid user code is entered - LED1 to
LED6 do not light
Bell time at address 42 - LED1 ot LED6 light
TA MPER ALA RM 49
Audible alarm signel TAMPER disabled in
Disarm mode - LED1 to LED6 do not light
Audible alarm signel TAMPER enabled in
Disarm mode - LED1 to LED6 light
ENGINEER CODE 50 DIGIT 1 DIGIT 2 DIGIT 3 DIGIT 4
RESET ENA BLE 51 NO - LED1 to LED6 do not light Y ES - LED1 to LED6 light
DEFA ULT SETTINGS 52
PA RT. RESET 53
Press the keys from 1 to 6 consequently and confirm by ENTER
Clock setting ( HH:MM). Default -> 00:00.
Date setting ( dd:mm). Default -> 01.01.
Telephone line fault indication delay (0-99 MIN). Def ault -> 0.
Press the keys from 1 to 6 consequently and confirm by ENTER
0- 99 SEC. Def ault - > 45.
0- 99 SEC. Def ault - > 15.
0-99 MIN. Default -> 3.
0-99 SECDefault -> 0.
Number of activations (0 to 9). Default -> 0.
DUAL - LED1 to LED6 do not light
UNUSED \
E- E
\ FOLOW \ INSTANT \ 24h \ FIRE \ PANIC \ TAMPER \ MEDICAL \ SWITCH
UNUSED \ E-E \
FOLOW
\ INSTANT \ 24h \ FIRE \ PANIC \ TAMPER \ MEDICAL \ SWITCH
UNUSED \ E-E \ FOLOW \
INSTANT
\ 24h \ FIRE \ PANIC \ TAMPER \ MEDICAL \ SWITCH
UNUSED \ E-E \ FOLOW \
INSTANT
\ 24h \ FIRE \ PANIC \ TAMPER \ MEDICAL \ SWITCH
UNUSED \ E-E \ FOLOW \ INSTANT \ 24h \ FIRE \
PANIC
\ TAMPER \ MEDICAL \ SWITCH
UNUSED \ E-E \ FOLOW \ INSTANT \ 24h \ FIRE \ PANIC \
TAMPER
\ MEDICA L \ SWITCH
Number of activations (0 to 9). Default -> 6.