56 SUPPLEMENTS - СА62 Alarm Control Panel
ADDRESS MENU
DEFAULT CONFIGURATION 0
DEFAULT
CONFIG. 1
DEFAULT
CONFIG. 2
DEFAULT
CONFIG. 3
LED 1 LED 2 LED 3 LED 4 LED 5 LED 6
4020 Exit time Part B Enter Exit time for Part B (0-99 sec). Settings at RESET → 45. 45 45 45
4021 Entry time Part B Enter Entry time for Part B (0-99 sec). Settings at RESET → 15. 15 15 15
4022 Bell time Part B 0-99 min. Settings at RESET → 3. 3 3 3
4023 Bell delay Part B 0-99 min. Settings at RESET → 0. 0 0 0
4024 Auto ARM time Part B Enter time (HH:MM) for Automatic ARM of Part B. Settings at RESET → 00:00. 00:00 00:00 00:00
4025
FIRE Duration Part B
Until a valid user code -
LEDs off
Bell Time at ADDRESS 4022 -
LEDs on
Valid Code Valid Code Valid Code
4026 ATTRIBUTES Part B 1. Sqwk ARM 2. Sqwk DISARM 3. Auto-Arm Enbl 4. Arm Full / Stay
4027
Communication account
Part B
Communication account for Part B - 4 digits (from 0 to 9 + symbols А to F).
Settings at RESET → FFFF.
9999 9999 9999
6. PROGRAMMING OF COMMUNICATION DEVICES
6001 Communication attempts From 0 to 9 attempts. Settings at RESET -> 0, meaning 4 attempts 0, 4 attempts 0, 4 attempts 0, 4 attempts
6002 Test period Enter the duration of the test period - from 00 to 99 hours. Settings at RESET → 24. 24 24 24
6003 Test start time Enter the time for starting test period (HH:ММ). Settings at RESET → 00:05. 00:05 00:05 00:05
6010 Telephone number 1
Max. phone number length - 16 symbols, pulse dialing=ARM+0, DTMF dialing=ARM+1,
pause=ARM+2, Enabling "Dial tone detector"=ARM+3, Disabling "Dial tone detector" =ARM=4, clear
number=ARM+5. Default settings at RESET -> no number.
no tel.
number
no tel.
number
no tel.
number
6011 Comm. Protocol 1 Enter communication protocol number (1 - Contact ID; 2-SIA). Settings at RESET → 2-SIA. 2 2 2
6012 Messages 1. ALARM 2. PANIC 3. FIRE 4. ON/OFF+BPS 5. MEDICAL 6. TROUBLE from 1 to 6 from 1 to 6 from 1 to 6
6020 Telephone number 2
Max. phone number length - 16 symbols, pulse dialing=ARM+0, DTMF dialing=ARM+1,
pause=ARM+2, Enabling "Dial tone detector"=ARM+3, Disabling "Dial tone detector" =ARM=4, clear
number=ARM+5. Default settings at RESET -> no number.
no tel.
number
no tel.
number
no tel.
number
6021 Comm. Protocol 2 Enter communication protocol number (1 - Contact ID; 2-SIA). Settings at RESET → 2-SIA. 2 2 2
6022 Messages 1. ALARM 2. PANIC 3. FIRE 4. ON/OFF+BPS 5. MEDICAL 6. TROUBLE
6030 VD60 Programming Records and Playback voice message into voice dialer VD60
6031
Dialer VD60
Telephone number 1
Max. phone number length - 16 symbols, pulse dialing=ARM+0, DTMF dialing=ARM+1,
pause=ARM+2, Enabling "Dial tone detector"=ARM+3, Disabling "Dial tone detector" =ARM=4, clear
number=ARM+5. Default settings at RESET -> no number.
no tel.
number
no tel.
number
no tel.
number
6032
Dialer VD60
Telephone number 2
Max. phone number length - 16 symbols, pulse dialing=ARM+0, DTMF dialing=ARM+1,
pause=ARM+2, Enabling "Dial tone detector"=ARM+3, Disabling "Dial tone detector" =ARM=4, clear
number=ARM+5. Default settings at RESET -> no number.
no tel.
number
no tel.
number
no tel.
number
6033
Dialer VD60
Telephone number 3
Max. phone number length - 16 symbols, pulse dialing=ARM+0, DTMF dialing=ARM+1,
pause=ARM+2, Enabling "Dial tone detector"=ARM+3, Disabling "Dial tone detector" =ARM=4, clear
number=ARM+5. Default settings at RESET -> no number.
no tel.
number
no tel.
number
no tel.
number
6034
Dialer VD60
Telephone number 4
Max. phone number length - 16 symbols, pulse dialing=ARM+0, DTMF dialing=ARM+1,
pause=ARM+2, Enabling "Dial tone detector"=ARM+3, Disabling "Dial tone detector" =ARM=4, clear
number=ARM+5. Default settings at RESET -> no number.
no tel.
number
no tel.
number
no tel.
number
TABLE 1 continues