SUPPLEMENTS - СА62 Alarm Control Panel 55
3026 PGM 2 Extension Х3 Code 13 Code 14 Code 15 Code 16 Code 17 Code 18
3027 PGM 2 Extension Х4 Code 19 Code 20 Manager Manager 1 Manager 2 Manager 3
3028 PGM 2 Device ID Keyboard 1 Keyboard 2 Keyboard 3 Keyboard 4
3029 PGM 2 Device ID Proxi Reader 1 Proxi Reader 2
3030 PGM 3 Parameters 1 1. ALARM 2. PANIC 3. TAMPER 4. FIRE 5. FIRE RESET 6. ON / OFF
3031 PGM 3 Parameters 2 1. MEDICAL 2. PS/BYPASS 3. SIREN 4. TECH.TRBL 5. PULSE/LATCH 6. POLARITY 4, 6 4, 6 4, 6
3032 PGM 3 Attachment Part A Part B Part A Part A Part A
3033 PGM 3 Extension Choose an Extension number for PGM 3 (00 - 19). Setting at RESET → 00. No Extension 00 00 00
3034 PGM 3 Extension Х1 Code/ Zone 1 Code/ Zone 2 Code/ Zone 3 Code/ Zone 4 Code/ Zone 5 Code/ Zone 6
3035 PGM 3 Extension Х2 Code/ Zone 7 Code/ Zone 8 Code/ Zone 9 Code/ Zone 10 Code/ Zone 11 Code/ Zone 12
3036 PGM 3 Extension Х3 Code 13 Code 14 Code 15 Code 16 Code 17 Code 18
3037 PGM 3 Extension Х4 Code 19 Code 20 Manager Manager 1 Manager 2 Manager 3
3038 PGM 3 Device ID Keyboard 1 Keyboard 2 Keyboard 3 Keyboard 4
3039 PGM 3 Device ID Proxi Reader 1 Proxi Reader 2
3040 SIREN (PGM4) Parameters 1 1. ALARM 2. PANIC 3. TAMPER 4. FIRE 5. FIRE RESET 6. ON / OFF
3041 SIREN (PGM4) Parameters 2 1. MEDICAL 2. PS/BYPASS 3. SIREN 4. TECH.TRBL 5. PULSE/LATCH 6. POLARITY 3, 6 3, 6 3, 6
3042 SIREN (PGM4) Attachment Part A Part B Part A
3043 SIREN (PGM4) Extension Choose an Extension number for PGM 4 (00 - 19). Setting at RESET → 00. No Extension 00 00 00
3044 SIREN (PGM4) Extension Х1 Code/ Zone 1 Code/ Zone 2 Code/ Zone 3 Code/ Zone 4 Code/ Zone 5 Code/ Zone 6
3045 SIREN (PGM4) Extension Х2 Code/ Zone 7 Code/ Zone 8 Code/ Zone 9 Code/ Zone 10 Code/ Zone 11 Code/ Zone 12
3046 SIREN (PGM4) Extension Х3 Code 13 Code 14 Code 15 Code 16 Code 17 Code 18
3047 SIREN (PGM4) Extension Х4 Code 19 Code 20 Manager Manager 1 Manager 2 Manager 3
3048 SIREN (PGM4) Device ID Keyboard 1 Keyboard 2 Keyboard 3 Keyboard 4
3049 SIREN (PGM4) Device ID Proxi Reader 1 Proxi Reader 2
4. PARTITIONS PROGRAMMING
4010 Exit time Part A Enter Exit time for Part A (0-99 sec). Settings at RESET → 45. 45 45 45
4011 Entry time Part A Enter Entry time for Part A (0-99 sec). Settings at RESET → 15. 15 15 15
4012 Bell time Part A 0-99 min. Settings at → 3. 3 3 3
4013 Bell delay Part A 0-99 min. Settings at → 0. 0 0 0
4014 Auto ARM time Part A Enter time (HH:MM) for Automatic ARM of Part A. Settings at RESET → 00:00. 00:00 00:00 00:00
4015
FIRE Duration Part A
Until a valid user code -
LEDs off
Bell Time at ADDRESS 4012 -
LEDs on
Valid Code Valid Code Valid Code
4016 ATTRIBUTES Part A 1. Sqwk ARM 2. Sqwk DISARM 3. Auto-Arm Enbl 4. Arm Full / Stay
4017
Communication account
Part A
Communication account for Part A - 4 digits (from 0 to 9 + symbols А to F).
Settings at RESET → FFFF.
9999 9999 9999
TABLE 1 continues