54 SUPPLEMENTS - СА62 Alarm Control Panel
ADDRESS MENU
DEFAULT CONFIGURATION 0
DEFAULT
CONFIG. 1
DEFAULT
CONFIG. 2
DEFAULT
CONFIG. 3
LED 1 LED 2 LED 3 LED 4 LED 5 LED 6
2110 Zone 11 type Choose the type of ZONE 11 (0 - 9). Setting at RESET → 0. UNUSED 0. UNUSED 0. UNUSED 0. UNUSED
2111 ZONE 11 ATTRIBUTES 1 1. AUTOBYPASS 2. BYPASS 3. STAY 4. FORCE 5. DOUBLE 6. E/E FINAL 2 2 2
2112 ZONE 11 ATTRIBUTES 2 1. Bell delay 2. Silent 3. VideoOnArmed 4. Write to LOG 5. Chime
2113 ZONE 11 ATTRIBUTES 3 1. Pulse / Latch 2. Full / Stay 3. Disarm Enable 3.Disarm En. 3.Disarm En. 3.Disarm En.
2114 ZONE 11 ATTRIBUTES AUX Choose the Attribute AUX for ZONE 11 (00 - 11).Setting at RESET → 00. 24h Burglary 00 00 00
2115 ZONE 11 Attachment Part A Part B Part A Part A Part A
2120 Zone 12 type Choose the type of ZONE 12 (0 - 9). Setting at RESET → 0. UNUSED 0. UNUSED 0. UNUSED 0. UNUSED
2121 ZONE 12 ATTRIBUTES 1 1. AUTOBYPASS 2. BYPASS 3. STAY 4. FORCE 5. DOUBLE 6. E/E FINAL 2 2 2
2122 ZONE 12 ATTRIBUTES 2 1. Bell delay 2. Silent 3. VideoOnArmed 4. Write to LOG 5. Chime
2123 ZONE 12 ATTRIBUTES 3 1. Pulse / Latch 2. Full / Stay 3. Disarm Enable 3.Disarm En. 3.Disarm En. 3.Disarm En.
2124 ZONE 12 ATTRIBUTES AUX Choose the Attribute AUX for ZONE 12 (00 - 11).Setting at RESET → 00. 24h Burglary 00 00 00
2125 ZONE 12 Attachment Part A Part B Part A Part A Part A
3.
PGM AND SIREN OUTPUTS PROGRAMMING
3010 PGM 1 Parameters 1 1. ALARM 2. PANIC 3. TAMPER 4. FIRE 5. FIRE RESET 6. ON / OFF 6 6 6
3011 PGM 1 Parameters 2 1. MEDICAL 2. PS/BYPASS 3. SIREN 4. TECH.TRBL 5. PULSE/LATCH 6. POLARITY 6 6 6
3012 PGM 1 Attachment Part A Part B Part A Part A Part A
3013 PGM 1 Extension
00. No Extension \ 01. Battery Trouble \ 02. Blown Fuse \ 03. Tel. Line Trouble \
04. AC Loss - Main board \ 05. AC Loss - Zone \ 06. Keypad Alarm \ 07. Keypad Fire Alarm\ 08. Keypad
Panic Alarm \ 09. AMBUHS Code \ 10. Chime \ 11. Auxiliary Alarm \
12. Battery Trouble \ 13. Wireless Transmitter Supervision Loss \
14. Wireless Transmitter Battery Low \ 15. Auto-ARM \ 16. Vide-On-Armed \
17. Zone Violation \ 18. Code Used Signalling \ 19. Proximity Card Used Signalling
00 00 00
3014 PGM 1 Extension Х1 Code/ Zone 1 Code/ Zone 2 Code/ Zone 3 Code/ Zone 4 Code/ Zone 5 Code/ Zone 6
3015 PGM 1 Extension Х2 Code/ Zone 7 Code/ Zone 8 Code/ Zone 9 Code/ Zone 10 Code/ Zone 11 Code/ Zone 12
3016 PGM 1 Extension Х3 Code 13 Code 14 Code 15 Code 16 Code 17 Code 18
3017 PGM 1 Extension Х4 Code 19 Code 20 Manager Manager 1 Manager 2 Manager 3
3018 PGM 1 Device ID Keyboard 1 Keyboard 2 Keyboard 3 Keyboard 4
3019 PGM 1 Device ID Proxi Reader 1 Proxi Reader 2
3020 PGM 2 Parameters 1 1. ALARM 2. PANIC 3. TAMPER 4. FIRE 5. FIRE RESET 6. ON / OFF 1, 3 1, 3 1, 3
3021 PGM 2 Parameters 2 1. MEDICAL 2. PS/BYPASS 3. SIREN 4. TECH.TRBL 5. PULSE/LATCH 6. POLARITY 6 6 6
3022 PGM 2 Attachment Part A Part B Part A Part A Part A
3023 PGM 2 Extension Choose an Extension number for PGM 2 (00 - 19). Setting at RESET → 00. No Extension 00 00 00
3024 PGM 2 Extension Х1 Code/ Zone 1 Code/ Zone 2 Code/ Zone 3 Code/ Zone 4 Code/ Zone 5 Code/ Zone 6
3025 PGM 2 Extension Х2 Code/ Zone 7 Code/ Zone 8 Code/ Zone 9 Code/ Zone 10 Code/ Zone 11 Code/ Zone 12
TABLE 1 continues