SUPPLEMENTS - СА62 Alarm Control Panel 53
2050 Zone 5 type Choose the type of ZONE 5 (0 - 9). Setting at RESET → 0. UNUSED 5. PANIC 2. FOLLOW 3. INSTANT
2051 ZONE 5 ATTRIBUTES 1 1. AUTOBYPASS 2. BYPASS 3. STAY 4. FORCE 5. DOUBLE 6. E/E FINAL 2 2 and 3 2
2052 ZONE 5 ATTRIBUTES 2 1. Bell delay 2. Silent 3. VideoOnArmed 4. Write to LOG 5. Chime
2053 ZONE 5 ATTRIBUTES 3 1. Pulse / Latch 2. Full / Stay 3. Disarm Enable 3.Disarm En. 3.Disarm En. 3.Disarm En.
2054 ZONE 5 ATTRIBUTES AUX Choose the Attribute AUX for ZONE 5 (00 - 11).Setting at RESET → 00. 24h Burglary 00 00 00
2055 ZONE 5 Attachment Part A Part B Part A Part В Part B
2056 ZONE 5 Hardware 1. EOL 2. Fast/ Regular 3.Power-up Delay 4.DOUBLING
2060 Zone 6 type Choose the type of ZONE 6 (0 - 9). Setting at RESET → 0. UNUSED 6. TAMPER 3. INSTANT 3. INSTANT
2061 ZONE 6 ATTRIBUTES 1 1. AUTOBYPASS 2. BYPASS 3. STAY 4. FORCE 5. DOUBLE 6. E/E FINAL 2 and 3 2
2062 ZONE 6 ATTRIBUTES 2 1. Bell delay 2. Silent 3. VideoOnArmed 4. Write to LOG 5. Chime
2063 ZONE 6 ATTRIBUTES 3 1. Pulse / Latch 2. Full / Stay 3. Disarm Enable 3.Disarm En. 3.Disarm En. 3.Disarm En.
2064 ZONE 6 ATTRIBUTES AUX Choose the Attribute AUX for ZONE 6 (00 - 11).Setting at RESET → 00. 24h Burglary 00 00 00
2065 ZONE 6 Attachment Part A Part B Part A Part В Part B
2066 ZONE 6 Hardware 1. EOL 2. Fast/ Regular 3.Power-up Delay 4.DOUBLING
2070 Zone 7 type Choose the type of ZONE 7 (0 - 9). Setting at RESET → 0. UNUSED 0. UNUSED 0. UNUSED 0. UNUSED
2071 ZONE 7 ATTRIBUTES 1 1. AUTOBYPASS 2. BYPASS 3. STAY 4. FORCE 5. DOUBLE 6. E/E FINAL 2 2 2
2072 ZONE 7 ATTRIBUTES 2 1. Bell delay 2. Silent 3. VideoOnArmed 4. Write to LOG 5. Chime
2073 ZONE 7 ATTRIBUTES 3 1. Pulse / Latch 2. Full / Stay 3. Disarm Enable 3.Disarm En. 3.Disarm En. 3.Disarm En.
2074 ZONE 7 ATTRIBUTES AUX Choose the Attribute AUX for ZONE 7 (00 - 11).Setting at RESET → 00. 24h Burglary 00 00 00
2075 ZONE 7 Attachment Part A Part B Part A Part A Part A
2080 Zone 8 type Choose the type of ZONE 8 (0 - 9). Setting at RESET → 0. UNUSED 0. UNUSED 0. UNUSED 0. UNUSED
2081 ZONE 8 ATTRIBUTES 1 1. AUTOBYPASS 2. BYPASS 3. STAY 4. FORCE 5. DOUBLE 6. E/E FINAL 2 2 2
2082 ZONE 8 ATTRIBUTES 2 1. Bell delay 2. Silent 3. VideoOnArmed 4. Write to LOG 5. Chime
2083 ZONE 8 ATTRIBUTES 3 1. Pulse / Latch 2. Full / Stay 3. Disarm Enable 3.Disarm En. 3.Disarm En. 3.Disarm En.
2084 ZONE 8 ATTRIBUTES AUX Choose the Attribute AUX for ZONE 8 (00 - 11).Setting at RESET → 00. 24h Burglary 00 00 00
2085 ZONE 8 Attachment Part A Part B Part A Part A Part A
2090 Zone 9 type Choose the type of ZONE 9 (0 - 9). Setting at RESET → 0. UNUSED 0. UNUSED 0. UNUSED 0. UNUSED
2091 ZONE 9 ATTRIBUTES 1 1. AUTOBYPASS 2. BYPASS 3. STAY 4. FORCE 5. DOUBLE 6. E/E FINAL 2 2 2
2092 ZONE 9 ATTRIBUTES 2 1. Bell delay 2. Silent 3. VideoOnArmed 4. Write to LOG 5. Chime
2093 ZONE 9 ATTRIBUTES 3 1. Pulse / Latch 2. Full / Stay 3. Disarm Enable 3.Disarm En. 3.Disarm En. 3.Disarm En.
2094 ZONE 9 ATTRIBUTES AUX Choose the Attribute AUX for ZONE 9 (00 - 11).Setting at RESET → 00. 24h Burglary 00 00 00
2095 ZONE 9 Attachment Part A Part B Part A Part A Part A
2100 Zone 10 type Choose the type of ZONE 10 (0 - 9). Setting at RESET → 0. UNUSED 0. UNUSED 0. UNUSED 0. UNUSED
2101 ZONE10 ATTRIBUTES 1 1. AUTOBYPASS 2. BYPASS 3. STAY 4. FORCE 5. DOUBLE 6. E/E FINAL 2 2 2
2102 ZONE10 ATTRIBUTES 2 1. Bell delay 2. Silent 3. VideoOnArmed 4. Write to LOG 5. Chime
2103 ZONE 10 ATTRIBUTES 3 1. Pulse / Latch 2. Full / Stay 3. Disarm Enable 3.Disarm En. 3.Disarm En. 3.Disarm En.
2104 ZONE 10 ATTRIBUTES AUX Choose the Attribute AUX for ZONE 10 (00 - 11).Setting at RESET → 00. 24h Burglary 00 00 00
2105 ZONE 10 Attachment Part A Part B Part A Part A Part A
TABLE 1 continues