D-Cerno Wired System
Installation and User Manual
Televic Conference Systems
V0.4 - December 6, 2012
57
15. System update
procedure
If an update of the system is advised you will
need 4 files for the 4 parts of the update:
host_x-xx-xx.mcs, peripheral_x-xx-xx.mcs,
web_x-xx-xx.img and os_x-xx-xx.ubi, where the
x-xx-xx is replaced by the current version.
The latest version is available for download from
the partner-domain. The complete update
procedure takes about 20 minutes.
1. Firmware CU: By clicking on “Choose file” a
pop-up window appears. Please choose the file
“host_x-xx-xx.mcs”. Then press “Upload”.
Then the following is shown:
Press “Start update” to start the update. This
takes around 15 minutes to complete the first
parts. Under “Status”: you see the current
status. When completed the status changes to
“Update completed successfully!”. Then press
“Back” to go to the second part and restart the
central unit.
2. Firmware units: Before uploading a new file,
please manually restart the central unit and re-
open the webbrowser. Then choose the file:
“peripheral_x-xx-xx.mcs” and click “Upload”.
Then again a new screen is shown where the
status says Waiting to start…”. Press “Start
update”. The update takes a couple of minutes.
During the update the light ring of the delegate
units should blink and after completion the total
number of update units should correspond with
the actual number of units connected to the
central unit. If this is not the case it is advised to
do the same update procedure a second time.
(Again restart both Central Unit and
webbrowser).
3. Webpages: Choose the file web_x-xx-xx.ubi”
and press “Upload”, “Start update”. The update
takes about 1 minute. After completion please
restart both webserver and central unit.
Note:
After each part of the update, please do
a restart of the Central Unit to make
sure it starts with the latest uploaded
version. Also close and re-open the web
browser.
Note:
If an update is done, please do an
update of all files. By doing this you are
100% sure all files are up to date.