8 Using the product
34
Carry out the measurement
The silicone hose must be clear (pressureless, no kinks).
1
Start measurement: select [Start]
with the right function key.
Pressure zeroing.
2
Connect the silicone hose to the sampling point.
3
Pressurise the system.
The reading is displayed.
4
Quit measurement: select [Stop] with the right function key.
After the measurement
1
Open filter chamber of the flue gas probe: turn it gently anti-clockwise.
2
Remove the sealing plug from the gas path.
3
Insert the particle filter again into the gas path and check that it is fitted
securely.
4
Close filter chamber of the flue gas probe.
5
Remove silicone hose from the probe shaft.