2 Safety and the environment
7
Pos: 21 /TD/Sic herheit und Umwelt/Sicher heit gewährleiste n/vor Ort gültige Sic herheitsbestimmungen be achten @ 0\mod_11869971 07328_79.docx @ 2298 @ @ 1
> The objects to be measured or the measurement environment
may also pose risks: Note the safety regulations valid in your
area when performing the measurements.
Pos: 22 /TD/Sic herheit und Umwelt/Sicher heit gewährleiste n/Akku-Sicherhei tshinweise (LiIon) @ 0\mod_1187184666109_79. docx @ 2363 @ @ 1
> Improper use of rechargeable batteries can lead to destruction
or injuries by means of current surges, fire or escaping
chemicals. The following instructions must be observed to avoid
such hazards:
Only use in accordance with the directions in the instruction
manual.
Do not short, take apart or modify.
Do not expose to heavy impacts, water, fire or temperatures
above 60 °C.
Do not store in the proximity of metal objects.
Do not use leaky or damaged rechargeable batteries. In the
event of contact with battery acid: Thoroughly wash affected
area with water and consult a doctor, if necessary.
Only charge in the instrument or the recommended charging
station.
Immediately stop the charging process if this is not
completed in the given time.
In the event of improper function or signs of overheating,
immediately remove the rechargeable battery from the
measuring instrument/charging station. Caution:
Rechargeable battery may be hot!
Pos: 23 /TD/Übersc hriften/2.3 Umwel t schützen @ 0\mod_117378084 3645_79.docx @ 375 @ 2 @ 1
2.3. Protecting the environment
Pos: 24.1 /TD/Si cherheit und Umwelt/ Umwelt schützen/Akkus/ Batterien entsorgen @ 0\mod_1175693637007_ 79.docx @ 619 @ @ 1
> Dispose of faulty rechargeable batteries/spent batteries in
accordance with the valid legal specifications.
Pos: 24.2 /TD/Sic herheit und Umwelt/U mwelt schützen/Produk t entsorgen @ 0\mod_1173780 307072_79.doc x @ 357 @ @ 1
> At the end of its useful life, send the product to the separate
collection for electric and electronic devices (observe local
regulations) or return the product to Testo for disposal.
Pos: 25 /TD/Übersc hriften/3. Leistu ngsbeschreibung @ 0\mod_1 173774791554_79.d ocx @ 301 @ 1 @ 1

Other manuals for TESTO 310

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO 310 and is the answer not in the manual?

TESTO 310 Specifications

General IconGeneral
Measurement ParametersO2, CO, CO2, Draft, Pressure, Temperature
O2 Measurement Range0 to 21%
CO Measurement Range0 to 4000 ppm
Product TypeCombustion Analyzer
Power SupplyRechargeable battery
Protection ClassIP40
InterfacesUSB
Warranty2 years
Pressure Measurement Range-40 to +40 hPa
Battery Life10 hours
DisplayLCD
Storage Conditions-20 to +50 °C, 10 to 90% RH non-condensing
Operating Conditions5 to 45 °C, 10 to 90% RH non-condensing