www.ti.com
User Interface Overview
5
DLPU074A–August 2018–Revised October 2019
Submit Documentation Feedback
Copyright © 2018–2019, Texas Instruments Incorporated
DLP
®
Display and Light Control EVM GUI Tool
In addition to the EVM connection status, the page shows the Input Source or Operating Mode. When
connected, the Input shows one of the following:
• External video port
• Test pattern generator
• Splash screen
• External pattern streaming
• Internal pattern streaming
• Space coded pattern streaming
After the EVM is connected, if the tool used (DLPC2010LC or DLPC3010LC) does not match the EVM
being accessed (DLP2010EVM-LC or DLP3010EVM-LC) the EVM Status displays "Incompatible".
After the EVM is connected, click Get on the bottom-right corner to get the information and status of the
EVM. The Information page also lets user checks if any errors have occurred, checkmark(s) indicates
specific errors.
The following commands are used to obtain information about the EVM:
• Read short status (0xD0)
• Read system status (0xD1)
• Read DMD device ID (0xD5)
• Read controller device ID (0xD4)
• Write PAD register address (0xEC)
• Read PAD register (0xED)
• Read system software version (0xD2)
• Read flash build version (0xD9)
• Read system temperature (0xD6)