EasyManua.ls Logo

Teze TW-EOR48 - Charging Modes and Time-Slot Functionality; Solar Priority Output (SOL); Inverter Priority Output (SBU); Hybrid Charging Mode (SNU)

Default Icon
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Add: Building A, Xinlida Industrial Park, Junzibu Village,Guanlan Street, Longhua District ,Shenzhen,
Guangdong
TEL :0755-23225527 FAX:0755-23225537
30
Solar Priority Output 01 SOL
Solar provides power to the loads as first priority. If solar is not available, the utility will be used as a
supplement to provide power to the loads. This mode maximises solar energy while maintaining
battery power and is suitable for areas with relatively stable power grids.(Priority: solar>utility>battery)
Inverter Priority Output 01 SBU
Solar provides power to the loads as first priority. If solar is not sufficient or not available, the battery
will be used as a supplement to provide power to the loads. When the battery voltage reaches the
value of parameter 04 (Voltage point of battery switch to utility ) will switch to utility to provide power
to the load, This model makes maximum use of DC energy and is used in areas where the grid is stable.
(Priority: solar>battery>utility)
6.3 Battery charging mode
The charging mode corresponds to parameter setting item 06, which allows the user to set the
charging mode manually.
Hybrid Charging SNU(default)
Solar and utility charging the battery at the same time, solar at the first priority, utility power as a
supplement when solar power is not sufficient. This is the fastest way to charge and is suitable for
areas with low power supply, providing customers with sufficient back-up power.(Source priority:
solar>utility)