EasyManua.ls Logo

Teze TW-EOR48 - User Manual

Default Icon
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...

Questions and Answers

Summary

Company Profile

Inverter All-in-one Machine Features

Long Life and Safety Features

Ensures durability and operational safety through integrated design and robust construction.

Ease of Installation and Use

Designed for straightforward setup and user-friendly operation, minimizing installation time and complexity.

Multiple Working Modes

Offers various operational modes to adapt to different power supply needs and environmental conditions.

Fast and Flexible Charging

Supports diverse charging methods, enabling efficient and adaptable power replenishment for optimal performance.

Scalability Options

Provides flexibility with multiple output voltage options to cater to a wide range of user requirements.

Product Instructions and Safety

How to Use This Manual

Guidance on navigating and utilizing the information provided within the user manual effectively.

Symbols in This Manual

Explanation of symbols used throughout the manual to convey important warnings, cautions, and notices.

Safety Instructions

Essential safety guidelines for installation and operation to prevent hazards like electric shock and equipment damage.

Production and Installation Guide

Production Instructions

Details on the production process and operational guidelines for the equipment.

Product Features Overview

Highlights key technical features and capabilities of the product.

System Connection Diagram

Visual representation of how the system components connect, illustrating the overall setup.

Production Overview

A general overview of the product's physical components and their arrangement.

Installation Procedures

Inspection of Outer Package

Guidelines for checking the product's packaging for any signs of damage before unpacking.

Inspection of Deliverables

Procedure for verifying that all included items are present and undamaged after unpacking.

Select Mount Location

Criteria and considerations for choosing the optimal and safe location for mounting the equipment.

Connection and Wiring Guide

Three-Phase Output Connection

Details on how to establish a three-phase output connection for the inverter.

Cable and Circuit Breaker Requirements

Specifications for selecting appropriate cables and circuit breakers for safe and efficient operation.

AC Input and Output Connection

Instructions for correctly connecting the AC input and output terminals of the inverter.

PV Connection

Guidelines for safely and correctly connecting the photovoltaic (PV) modules to the inverter.

Dry Contact Connection

Information on connecting the dry contact interface for external control or signaling purposes.

Grounding Connection

Procedure for ensuring proper grounding of the equipment to enhance safety and system stability.

Active Equilibrium Function

Details on the optional active equilibrium function for battery management and performance.

Startup and Operation Procedures

Final Assembly and Inverter Startup

Steps for completing assembly and safely powering on the inverter.

Operation and Display Panel Overview

Introduction to the inverter's control panel, including buttons and indicators.

Battery Display and Information

Viewing Analog Battery Information

How to access and view battery voltage, current, and temperature readings.

Battery Cell Voltage and Capacity Details

Accessing information on individual cell voltages and overall battery capacity status.

BMS Status and Battery Alarms

Monitoring the Battery Management System (BMS) status and interpreting alarm codes.

Inverter Display and Controls

Inverter Display Panel and Buttons

Overview of the inverter's LCD screen, operation buttons, and their functions.

Inverter LED Indicator Status

Explanation of LED indicators for AC/INV, CHARGE, and FAULT signals.

Display Panel Icons and Functions

Inverter Display Panel Icon Guide

Visual guide to understanding the meaning of various icons on the inverter display.

Inverter Display Function Icons

Description of icons representing PV panel, battery, utility grid, home load, and energy flow.

Icon Function Descriptions

Load Power and Battery SOC Indicators

Details the indicators for load power levels and battery State of Charge (SOC).

System Status and Protection Indicators

Explanation of icons for system communication, voltage, current, and protection statuses.

Battery Type and Mode Indicators

Description of icons for battery types, energy-saving modes, and output priorities.

Real-Time Data and Settings

Viewing Real-Time Inverter Data

Instructions on accessing live operational data via the inverter's main screen.

Inverter Data Parameter Table

Table detailing parameters for PV, Battery, AC IN, LOAD, and General sections for monitoring.

System Settings and Parameters

Setting Menu Navigation

Guide to navigating the setup menu to view and edit various system parameters.

AC Output Source Priority

Configuration options for prioritizing AC output sources, such as utility, PV, or battery power.

AC Output Frequency Settings

Adjusting the AC output frequency to match grid requirements or specific load needs.

Battery Switch Voltage Points

Setting voltage thresholds for switching the AC output source between utility and battery power.

Battery Charging Mode Configuration

Selecting and configuring the battery charging mode, including hybrid and priority settings.

Battery Charging and Type Settings

Battery Charging Current and Type

Setting the maximum charging current and selecting the appropriate battery type for optimal performance.

Battery Voltage Settings

Configuration of bulk, float, and under-voltage parameters for battery charging and protection.

Battery Equalization Settings

Parameters for battery equalization charging duration and interval to maintain battery health.

Advanced Battery and Power Settings

Battery Over-discharge Protection

Settings to prevent battery damage from over-discharging, including voltage limits and delay times.

Power Saving and Overload Restart

Configuration of power saving modes and automatic restart behavior for overload conditions.

Buzzer and Source Switching Reminders

Enabling or disabling buzzer alarms and reminders for power source changes.

Inverter Overload Switch to Bypass

Setting the inverter to bypass to mains power during overload events for continuous operation.

Communication Settings

Configuration of communication interfaces like RS485, BMS, and CAN for data monitoring and control.

Time-Slot Functions and Battery Parameters

Battery Under-Voltage Recover Point

Setting the voltage threshold for restoring AC output after a battery under-voltage condition.

Battery Full Recharge Voltage

Defining the voltage point at which the battery is considered fully charged and charging stops.

Time Slot Charging;Discharging

Setting specific time periods for charging and discharging to optimize energy usage and costs.

AC Output Modes

Utility Priority Output (UTI)

Prioritizes utility power, using solar and battery as supplements when utility is unavailable.

Solar and Utility Hybrid Output (MIX LOD)

Combines solar and utility power for the load, with battery as a backup.

Charging Modes and Time-Slot Functionality

Solar Priority Output (SOL)

Prioritizes solar power, using utility as a supplement when solar is insufficient.

Inverter Priority Output (SBU)

Prioritizes solar and battery power, switching to utility only when battery voltage is low.

Hybrid Charging Mode (SNU)

Charges the battery using both solar and utility power, with solar as the primary source.

Charging Strategies and Time-Slot Operation

Utility Priority Charging (CUB)

Prioritizes utility for battery charging; PV charging activates only when utility is unavailable.

Solar Priority Charging (CSO)

Prioritizes solar charging; utility charging is enabled when solar fails.

Only Solar Charging (OSO)

Utilizes solar energy exclusively for battery charging, maximizing energy efficiency.

Time-Slot Charging;Discharging Function

Enables setting custom charging and discharging periods based on local peak and valley electricity tariffs.

Time-Slot Scheduling and Battery Parameters

Peak-Valley Electricity Tariff Setup

Guide for setting local time and peak/valley tariffs to configure time-slot functions accurately.

Time-Slot Utility Charging;Carrying

Configures mains charging and load carrying periods, prioritizing PV or utility energy.

Time-Slot Battery Discharging

Sets battery discharge periods, prioritizing battery power for the load or switching to mains.

Li-ion Battery Parameters

Detailed parameters for Li-ion batteries, including voltage limits, charging settings, and type specifications.

Battery Charging Parameters

Discharging Limit Voltage and Delay Time

Setting limits for discharging voltage and delays to protect the battery from over-discharge.

Equalization Charging Settings

Configuration for equalization charging duration and interval to optimize battery health.

Bulk Charging Duration

Setting the duration for the bulk charging stage to ensure efficient battery replenishment.

Communication Interface Overview

Inverter Communication Ports

Identification and description of ports for inverter communication, including RS485, USB, and CAN.

Battery Communication Interface

Overview of the battery communication interface, including LED indicators and connection ports.

Inverter Communication Ports

RS485-1 Port for Data Acquisition

Details on using the RS485-1 port to connect data acquisition modules for mobile app monitoring.

USB-B Port for Host Computer

Instructions for using the USB-B port to connect host computers for parameter management.

CAN;RS485-2 and Dry Contact Ports

CAN;RS485-2 Port for BMS

Information on connecting the CAN/RS485-2 port to the BMS of Li-ion batteries.

Dry Contact Port Functions

Description of the four functions available through the dry contact port for external control.

Battery Communication Indicators

LED Indicator Overview

Description of the LED indicators on the battery communication interface.

SOC Capacity Indicator Lamp

Explanation of the capacity indicator lamps for State of Charge (SOC) during charge and discharge.

Running Indicator Light

Details on the running indicator light status for monitoring operational activity.

Status Indicators and Flashing Descriptions

Status Indicator Table

Comprehensive table detailing status indicators for shutdown, standby, charge, discharge, and invalid states.

LED Flashing Mode Explanations

Description of different LED flashing modes (Flash 1, 2, 3) and their corresponding timing.

Communication Area and Interfaces

Communication Port Functions

Overview of RS232, RS485, CAN, and DCT communication port functionalities.

Interface Diagrams

Visual diagrams illustrating the CAN, RS485, Dry contact, and communication interfaces.

RS232 Electrical Interface Definition

Pin definition for the RS232 interface, detailing connections for TX, RX, GND, and NC.

RS485 and Parallel Communication Port Pinouts

RS485 and CAN Interface Pinouts

Pin assignment details for RS485 and CAN interfaces using RJ45 sockets.

Parallel Communication Port Pinouts

Pin assignment details for parallel communication ports using RJ45 sockets.

Fault Codes and Meanings

Fault Code Table

List of fault codes, their meanings, impact on outputs, and recommended instructions for resolution.

Battery-Related Faults

Specific fault codes related to battery voltage, current, and connection issues.

Inverter and PV Related Faults

Fault codes pertaining to inverter operation, PV input, and communication errors.

Troubleshooting Common Issues

Troubleshooting Table

Guidance on diagnosing and resolving common issues like screen display problems and battery connectivity.

Battery Voltage and Connectivity Issues

Solutions for battery under-voltage, disconnection, and over-discharge problems.

System and BMS Faults

Troubleshooting steps for system communication failures, BMS errors, and temperature or voltage alarms.

Protection Features and Maintenance

PV Input Protection Features

Protection mechanisms for PV input, including current limiting, over-voltage, and reverse current.

AC Input and Battery Protection

Protection features for AC input voltage and battery over-voltage, under-voltage, and over-current.

Output and Heat Sink Protection

Protection against AC output short-circuits, heat sink over-temperature, and inverter overload.

Maintenance Recommendations

Regular maintenance checks recommended twice a year to ensure optimal performance and longevity.

Datasheet and Technical Specifications

Battery Technical Specifications

Detailed specifications for battery model, energy, capacity, voltage, current, and lifespan.

Inverter Technical Specifications

Technical details for the inverter, including PV charge, AC charge, and input voltage ranges.

AC Output and General Data

AC Output Specifications

Technical data for AC output, including rated power, voltage, frequency, waveform, and switch time.

General Data and Certifications

Information on protection degree, operating temperature, noise, warranty, communication, and certifications.

Optional Functions

Active Equilibrium Module

Details on the active equilibrium module, including qualification, balance modes, and working parameters.

Fire Extinguishing Equipment

Information about the fire extinguishing equipment, including its specifications and safety warnings.

About Us and Contact Information

Contact Information

Contact details including email, phone/fax, WhatsApp, and WeChat for inquiries and support.

Teze TW-EOR48 Specifications

General IconGeneral
BrandTeze
ModelTW-EOR48
CategoryBattery Pack
LanguageEnglish