Add: Building A, Xinlida Industrial Park, Junzibu Village,Guanlan Street, Longhua District ,Shenzhen,
Guangdong
TEL :0755-23225527 FAX:0755-23225537
31
Utility Priority Charging CUB
The utility power gives priority to charging the battery, and PV charging is only activated when the
utility power is not available.(Source priority: utility>solar)
Solar Priority Charging CSO
Solar priority charging, with utility charging only activated when the solar fails. By making full use of
solar power during the day and switching to utility charging at night, battery power can be maintained
and is suitable for applications in areas where the grid is relatively stable and electricity prices are
more expensive.(Source priority: solar>utility)
Only Solar Charging OSO
Solar charging only, no mains charging is activated. This is the most energy-efficient method, with all
the battery power coming from solar energy, and is usually used in areas with good radiation
conditions.
6.4 Time-slot charging/discharging function
The TEZE-AO-MB51400-380VAC-10KW-EU/TEZE-AO-MB51300-380VAC-10KW-EU series is
equipped with a time-slot charging and discharging function, which allows users to set different
charging and discharging periods according to the local peak and valley tariffs, so that the utility power
and PV energy can be used rationally.
When mains electricity is expensive, the battery inverter is used to carry the load; when the
mains electricity is cheap, the mains electricity is used to carry the load and charge, which can help
customers to save electricity costs to the greatest extent.
The user can turn on/off the time-slot charging/discharging function in setup menu parameter 46
and 53.and set charging and discharging slot in parameter 40-45, 47-52. Below are examples for users
to understand the function.