Triggers an alarm when the battery SOC is less than the
set value (unit:%, valid only when BMS communication
is normal)
Stops discharging when the battery SOC is less than the
set value (unit:%, valid only when BMS communication
is normal)
Stops charging when the battery SOC is higher than the
set value (unit:%, valid only when BMS communication
is normal)
Switch to utility power when the battery SOC is less
than this setting value (unit:%, valid only when BMS
communication is normal)
Switches to inverter output mode when SOC is higher
than this setting value (unit:%, valid only when BMS
communication is normal)
N-PE bonding automatic
switching function
Disable automatic switching of N-PE connections.
Enable automatic switching of N-PE connections.
you can set the max on-grid power(less than the
inverter rated power)
Insulation impedance
detection
Disable detecting insulation impedance value.
Enable detecting insulation impedance value.
PV energy is prioritized to supply the load;PV power
supply logic: Load-Grid-battery chgarge
PV energy is prioritized to charge the battery;PV power
supply logic: Battery chgarge-Load-Grid
6.2 AC output mode
The AC output mode corresponds to parameter setting item 01 and 34, which allows the user to set
the AC output power source manually.
Utility Priority Output 01 UTI (default)
Utility at first priority, utility and solar provide power to load at the same time when solar is available,
battery will provide power to load only when utility power is not available.(Priority:
utility>solar>battery)
Solar and Utility Hybrid Output 34 MIX LOD
In UTI mode, when not connected to the battery or when the battery is full, the solar and the utility
supply power to the load at the same time.(Priority: solar>utility>battery)