When parameter [01]=UTI, the solar energy is given
priority charging, and when the load demand is met,
the remaining power will be fed back to the grid.
Battery under voltage
recover point
When the battery is under-voltage, the battery voltage
needs to be higher than this setting value in order to
restore the battery inverter AC output, setting range:
44V~54.4V.
Battery full recharge
voltage point
Inverter stops charging when the battery is full.
Inverter resumes charging when the battery voltage
below this value. Setting range: 44V~54V.
Setting range: 200/208/220/230/240Vac.
Charging current
limiting method (when
BMS is enabled)
[SET] The maximum battery charging current is limited according to the
setting in [07].
[BMS] Default Maximum battery charging current is limited according to
the current limit value of the BMS.
[INV] Maximum battery charging current is limited by the machine's
derating logic.
Setting range: 00:00:00-23:59:00
Setting range: 00:00:00-23:59:00
Setting range: 00:00:00-23:59:00
Setting range: 00:00:00-23:59:00
Setting range: 00:00:00-23:59:00
Setting range: 00:00:00-23:59:00
Time slot charging
function
When the time slot mains charging / carrying loads
function is enabled, the power supply mode will
change to SBU and switch to mains charging only
during the set charging period or when the battery is
over-discharged. If the time slot discharging function is
enabled at the same time, the system power supply
mode will change to UTI, and will only switch to the
mains for charging during the set charging period, and
switch to the battery inverter power supply during the
set discharging period or when the mains is outaged.
1
st
slot start discharging
Setting range: 00:00:00-23:59:00
Setting range: 00:00:00-23:59:00
2
nd
slot start discharging
Setting range: 00:00:00-23:59:00
Setting range: 00:00:00-23:59:00
3
rd
slot start discharging
Setting range: 00:00:00-23:59:00
Setting range: 00:00:00-23:59:00
Time slot discharging
function
When the time slot battery discharging function is
enabled, the power supply mode will be switched to
UTI, and the system will switch to battery inverter
power supply only during the set discharge period or
when the mains is outaged.
YY/MM/DD.
Setting range: 00:01:01-99:12:31
Setting range: 00:00:00-23:59:59
Leakage current
detection protection
Disable detecting Leakage current value.
Enable detecting Leakage current value.
Charging stops when the charging current is less than