Operator Manual, Revision T-5 8-65
Fault This may mean Cause Solution
The error code
H08 appears�
And icon
flashes� No arc
output when
the trigger is
depressed or
the CNC start
signal is ON�
Consumables
fault�
Consumables are
loose, improperly
installed or missing�
Install the consumables and
fit the retaining cap
The retaining cap
is not installed or
tightened correctly
Fit the retaining cap and
correctly tighten�
Non original
consumables�
Use original new
consumables�
Short circuit
inside the torch�
Consumables are
loose, improperly
installed or missing�
Install the consumables
correctly
Dirt inside the
torch�
Remove all consumables,
clean the inside of the torch�
Reassemble in correct order
When switching
cutting modes
press the torch
trigger but no
gas output�
Gas valve or
power supply
fault�
Cable to the gas
valve disconnected�
Contact your distributor
Gas valve
malfunction�
Contact your distributor
Switch or trigger
malfunctioning�
Contact your distributor
No arc output
but no alarm
light when
torch trigger is
depressed or
the CNC start
signal is ON�
Torch fault� Incorrect torch type� Use the specified torch for
the machine�
Torch components� Check torch components,
change parts if necessary
Input gas
pressure fault�
Input gas pressure
is too high�
Decrease input static
pressure to 6 bar/87 psi�