EPD/HB/40521/000
ISSUE 5
EPD TECHNICAL HANDBOOK Page 73
EEPROM Module
Code Text as displayed by
EasyEPD2
EPD
Action
Recommended
Customer Action
Remarks
060 EEPROM no more spare
sectors available
Write
aband
oned.
Return to supplier All 9 spare sectors have been
used. This fault is unlikely to
occur in normal operation.
Tests have shown that the
EEPROMs are very resilient (
> 1 million bit toggles).
061 EEPROM bad sector,
requested sector number is
invalid
Return to supplier Th is fault is unlikely to occur.
062 EEPROM bad sector
access table entry (number
is invalid)
Return to supplier This fault is unlikely to occur,
Sector Access Table is
corrupted or EEPROM read
failed
063 EEPROM could not read
from the sector access
table area
Return to supplier Executes a Deferred Log
Fault with RECOVERED
option with the given fault
code but only if the EEPROM
fail bit is not set. If the
EEPROM fail bit is set the
fault is ignored to stop the
error store being flooded with
EEPROM faults.
064 EEPROM could not read
the next entry
Return to supplier -ditto-
065 EEPROM could not
reallocate data to a good
sector
Return to supplier -ditto-
066 EEPROM could not write
next entry
Return to supplier -ditto
Data Module
Code Text as displayed by
EasyEPD2
EPD
Action
Recommended
Customer Action
Remarks
070 Data Module Error Reserved for future use