4 Programming (SDK)
353
4.3.99 is_StopLiveVideo
USB 2.0
USB 3.0
USB 2.0
USB 3.0
Syntax
INT is_StopLiveVideo (HIDS hCam, INT Wait)
Description
is_StopLiveVideo() stops live mode or cancels a hardware triggered image capture in case the exposure has
not yet started.
Input parameters
hCam
Camera handle
Wait
IS_WAIT
The function waits until the image save is complete.
IS_DONT_WAIT
The function returns immediately. Digitizing the image is
completed in the background.
IS_FORCE_VIDEO_STOP
Digitizing is stopped immediately.
Return values
IS_INVALID_CAMERA_HANDLE
Invalid camera handle
IS_INVALID_PARAMETER
One of the submitted parameters is outside the valid
range or is not supported for this sensor or is not
available in this mode.
IS_NO_SUCCESS
General error message
IS_SUCCESS
Function executed successfully
IS_TIMED_OUT
A timeout occurred. An image capturing process could
not be terminated within the allowable period.
Related functions
is_FreezeVideo()
is_CaptureVideo()
is_SetDisplayMode()
223
177
322

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU223x and is the answer not in the manual?

THORLABS DCU223x Specifications

General IconGeneral
BrandTHORLABS
ModelDCU223x
CategorySecurity Camera
LanguageEnglish

Related product manuals