3-33
3
4st 9.9/15/20 2008
27) Flushing with Water
Flushing with water using drive cleaner 3
1. Remove propeller and thrust holder.
2. Close sub water strainer 2 with sticky tape.
Touching rotating propeller could lead to
injury. Be sure to remove propeller before
running engine on the land.
Exhaust gas contains carbon monoxide,
which will cause gas poisoning. Do not
start engine with outboard motor placed in
a closed area such as boat house.
Remove tape after flushing with water.
3. Attach driver cleaner 3 to water strainer 1 area.
4. Put water hose to driver cleaner 3 and run water.
5. Set gear shift to neutral (N) and start engine.
6. Check that cooling water check port discharges water, and
run engine for 3 to 5 minutes at low speed.
7. Stop engine and stop water supply, remove driver cleaner
3, and remove tape, and then, install propeller.
E_MFS20C_ch03_090105.qxd 09.1.20 5:23 PM ページ 33