Document Ref 947571-001 Rev 2 Page 2-15
Quantium 110 & 210 Installation Manual Site Preparation
G1" VR Pipe
with male thread
70
Driptray
height
Underside of dispenser
17
Terminate VR pipe
154mm below dispenser
Flange 1" 78mm
901320-001
152.5
943143-002 Rev 1
IMPORTANT
Assembly below the shear point
must be secured to the ground
frame (NOT dispenser frame)
NOTE : All threads must be
sealed using Loctite 577
900015-022
901596
901772
900416
943050-001
903184
U Clamp
Flame Arrester
G1"- G
3
4
" Nipple
(Under Clamp)
Nipple
VR Flexi
M10x45 Bolt
Risbridger Shear Valve
906069
900011-004
901859
900758-003
M10 Nut
Insulation Sleeve
Gasket
154
VR Connection with Risbridger Shear Valve & Flame Arrester for Ethanol
Kit 2 - Tokheim Part No 943143-002