Page 5-10 Document Ref 947571-001 Rev 2
Installation Quantium 110 & 210 Installation Manual
5.5.2 PIPEWORK - SUCTION DISPENSERS WITH EXTERNAL FILTER
Connections to the fuel supply pipes and the vapour return lines are accessible
from side A of the dispenser (see section 5.2 for identification of sides).
The dispenser is positioned with the filter box positioned above the relevant
fuel supply risers. If required, adapters should be fitted to the supply pipes.
The flexible connection (rigid for pressurised systems) should then be fitted
between the fuel supply risers and the filter box.
PAS V3 PUMPS WITH EXTERNAL FILTER BOX ONLY
1) Remove the protective covers on the fuel supply riser pipe and on the filter
box.
WARNING : BEWARE OF FUEL SPILLAGE.
2) Cut the rubber manchet to suit the riser pipe diameter
and fit over the pipe to cover the hole in the driptray.
3) Apply a sealant compound to the fuel supply riser
and to the inside of the flexible coupling.
4) Fit the flexible coupling to the fuel supply riser pipe.
Note : Hand tighten only at this point
5) Insert the top hat filter (provided in the installation
kit) into the flexible coupling.
6) Manoeuvre the flexible coupling into the correct
position, ready for securing to the filter box.
7) Insert the gasket between the filter box and the flange
on the flexible coupling.
8) Fit the flange to the filter box using the two screws
provided in the installation kit.
Note : Hand tighten only at this point.