Page 6-6 Document Ref 947571-001 Rev 2
Commissioning Quantium 110 & 210 Installation Manual
6.2.3 TEMPERATURE COMPENSATION FUNCTION
Refer to separate MPE Pulser Manual for more detailed information. To set the
temperature compensation (TC) function:-
Press 2 to enter SET UP menu.
The first parameter, DIRECTION, is displayed.
Press 7 to skip to next function.
The next parameter, TC, is displayed. Press F4 to
enter TC sub menu.
Press ON to start configuration.
A choice of menus will be displayed.
Press 1 to enter MAINTENANCE menu.
The next parameter, EC, is displayed. Press 7 to
skip to next function.
Press F4 to save and continue.
Press 7 to scroll through fuel density options:-
90 = unleaded 90 (750kg/m
3
)
95 = unleaded 95 (750kg/m
3
)
98 = unleaded 98 (755kg/m
3
)
D iesel = diesel (833kg/m
3
)
LPG = LPG (537kg/m
3
)
Or enter density value for different fuel type using
the numeric keys. Press F4 to save and continue.
Press F4 to continue.
Default OFF is displayed. Press 7 to change to ON.
IMPORTANT : TC must be OFF if EC is to be
performed.
Press F1 several times until the main menu is
displayed.
Press OFF to disable the UAK and allow it to be
disconnected safely.
MPE 01 . 07 D33F
1:MA 2:TST 3:SIM
1:EC 2:SET
3:SERV 4:ADC
PARAMETERS
Se t di rec t ion
PARAMETERS
Se t EC
PARAMETERS
Se t TC
Se t TC OFF
Se t TC ON
Se t TC ON
Fuel :90
Se t TC ON
Density: ----.-
TC Setting OK
En ter (F4)
MPE 01 . 07 D33F
1:MA 2:TST 3:SIM
UAM f o r WWC
Vers ion: 0107