Page 5-6 Document Ref 947571-001 Rev 2
Installation Quantium 110 & 210 Installation Manual
WASHER
min thickness = 2mm
min dia = 25mm
Underside of
dispenser driptray
M12 ANCHOR BOLT FOR
CONCRETE high tensile
100
Min depth into
concrete = 100mm
TYPICAL FIXING INTO THIRD PARTY GROUNDFRAME / SUMP
FRAME
M12 NUT
Alternative to nut & washer :-
Welded nut on groundframe
with min. 5 captured threads
M12 BOLT high tensile
WASHERS
min thickness = 2mm
min dia = 25mm
Steel groundframe/
sump frame
Underside of
dispenser driptray
5.4.2 FIXING TO GROUND
The following information relates to a typical Tokheim dispenser, unmodified
by the user, with no additional advertisement boards, canopies or items added
to the dispenser. Any such modifications may affect the stability and have
warranty/liability consequences.
IMPORTANT:- Tokheim dispensers must be secured to the ground using
all 4 mounting positions provided in the driptray - refer to the groundplan
drawings in section 3 for mounting hole positions.
TYPICAL FIXING INTO CONCRETE (NO GROUNDFRAME)
TYPICAL FIXING INTO TOKHEIM GROUNDFRAME
Nut insert
Tokheim groundframe
Underside of
dispenser driptray
M10 BOLT high tensile
WASHER