D4008 – EN EZ 2810 Operators Manual 23
2.7.0 Preload a Tare
For weighing containers after loading to exclude the weight of the container. If weight of container is
known, a Tare weight is preloaded in indicator and only the Net weight of the product is displayed.
2.8.0 Pre-Alarm
“Early Warning” for Preset. Pre-alarm activates the alarm buzzer and light at a weight or percentage
of preset value.
Enter 1103, then press to access
Pre-Tare.
Press to enable the option.
Press to return to weighing mode.
1. Press and hold for 3 seconds to
zero balance the indicator.
2. Add weight to container.
3. Enter known weight of unloaded container.
4. Press
5. Press
3
4
1
5
2
1. Enter 4001 press .
Repeatedly press choose weight
or percent.
2. Press .
3. Enter number to activate pre-alarm.
4. Press stores setting.
1
2
3
4
5

Table of Contents