Specifications
23
Specifications
Remote Controller Handle Unit RC-3H
Remote Controller RC-3R
Operating temperature : -20°C to +50°C
Storing temperature : -30°C to +60°C
Protection against water
and dust : RC-3R: IP65
RC-3H: IP54 (Based on the standard IEC60529)
Operating distance * 1) : 5m~400 m (16ft ~1310 ft)
(When using with the prism unit A6R/A6S)
* 1) The operating distance may be shorter than normal in such the
condition is not good by the heat simmer or strong direct sun
shine to the detector.
Turn-round operating
time : Approximately 10 seconds *2, 3)
Optical communicating
time : Approximately 3 to 4 seconds *2, 4)
* 2) Sight haze with visibility about 20km (12.5 miles) moderate
sunlight with light shimmer.
* 3) Under normal weather conditions, with the telescope turned
90° relative to the prism, and turn-around performed with the
prism roughly aligned vertical. (refer to “Reference : Turn-
round motions:” on page 17.)
* 4) Standard times for data display and data recording. Times may
vary depending on software version.
Number of optical
communication channels : 6
Power source : DC 7.4V from total station
Detective range : Horizontal : 360°
Vertical : ±30°
Weight : 0.3 kg
Dimensions : 58(D) × 166(W) × 71(H) mm
Weight : 0.3 kg
Dimensions : 122 (D)× 110 (W)× 46 (H) mm
Bluetooth™ Unit
Bluetooth™ Standard
:
Bluetooth™ Specification v1.2
Bluetooth™ profiles
:
Generic Access Profile
:
Service Discovery Application Profile
:
Serial Port Profile
BD Address
:
IEEE std802 48bit LAN MAC Address
Bluetooth™ Transmitting
:
Output Class2
Bluetooth™
Communication distance
:
About 5m
(The range will be different by a condition)