22
6. BASIC OPERATION
When the instrument system detects a shock, this function informs the operator of it.
When the instrument’s installation status (height) is sharply changed by the contact of the operator or the like,
this function stops self- leveling to keep the operation accuracy and informs the operator of the situation.
After 10 minutes has passed since the self- leveling function was activated and the laser beam was emitted,
this function works.
The height alert function will not operate while setting the dual axes grade in the Matching Mode, or Manual
Mode.
For more information about Height Alert ON/OFF, refer to"8.4 Height Alert ON/OFF"
PROCEDURE How to rest
1. Turn off the power switch.
2. Check whether the instrument is installed correctly.
3. Turn on the power switch. Self-leveling starts again. After
self-leveling is finished, the laser beam is emitted.
4. Make sure that the laser beam is set at the correct height.
Then, restart the operation.
6.2 Height Alert Function