11. SPECIFICATIONS
Light source Laser diode (Visible, 635 nm) Class1
(IEC60825-1 Ed. 3.0: 2014/FDA CDRH 21 CFR Part 1040.10
and 1040.11 (Complies with FDA performance standards for
laser products except for deviations pursuant to Laser Notice
No.56, dated May 8, 2019.))
Laser output 2.4 mW
Self-leveling range Horizontal ±5°
Vertical ±5°
Accuracy Horizontal ±10”
Vertical ±10
Grade setting range X: ±15%
Y: ±15% (2S only)
Manual slope settable range ±5° (When the instrument is installed on the 0° surface)
The slope range is increased or decreased according to the tilt
of the surface on which the instrument is installed.
Line control during vertical rotation ±5° (When the instrument is installed on the 0°surface)
Rotational speeds 300/600 r.p.m (Changeable)
Operating range Diameter Approx. 2 to 800 m or more (Rotational speed 600
r.p.m/When using LS-80X)
Bluetooth wireless communication*
1
Version Bluetooth 5.0 (Bluetooth Classic / Bluetooth Low Energy)
Transmission method FHSS
Modulation GFSK
Frequency band 2.402 to 2.480GHz
Bluetooth profile SPP, GATT(TOPCON Transfer Service)
Power class Class 1.5
Usable range Horizontal: 100m / Vertical: 20m (when placed vertically)
(good communication condition)*
23
Authentication Yes/No (selectable)
*1: Bluetooth function may not be built in depending on telecommunications regulations of the country or
the area where the instrument is purchased. Contact your local dealer for the details.
*2: With instrument height to be more than 1.2m, no obstacles (like building structures, trees or vehicles)
causing interrupting/reflecting radio wave, few sources of radio emissions/interference in the near
vicinity of the instrument, no rain.
*3: Usage range could be shorter depending on specifications of Bluetooth device to communicate.
Power source 4xD size dry batteries (alkaline)
Ni-MH battery pack BT-79Q (7000mAh)
Working duration at 20°C (68°F)*
4
Dry batteries (alkaline) 120 hours
BT-79Q 65 hours
Battery (BT-79Q) Ni-MH rechargeable battery
Nominal voltage 4.8V
Capacity 7,000mAh
Size 104(W) x 127(D) x 37(H) mm
Weight 690 g
AC/DC Converter (AD-15E)
Input voltage 100 to 240 V AC, 50 to 60 Hz, 0.6 A
Output voltage DC 9 V/2.0 MAX 18 W