28
7. APPLIED OPERATIONON
3. Horizontally rotate the laser beam of the RL-HV. (1S: X+0.000% /
2S: X+0.000%, Y+0.000%)
4. At Point B adjust the height of the LS-80X installed on a pole, align
the standard position of the LS-80X with the laser beam and fix.
5. Set the RL-HV at X+3.000% grade (1S) / at X+0.000% and Y-
3.000% grades (2S).
6. Align the RL-HV direction on top of the tripod so as to have the
laser beam in the ongrade position of the LS-80X in step 4.
• Do not change the height of the LS-80X installed on the pole.
If the height of the RL-HV is changed, return to step 3 and redo the adjustment.