Installation On Site SWINGDOOR Smart Drive 1101 T-1132 e
21
I
2
3
4
5
6
7
8
9
0
1.
2.
Teach-In
0
i
2
3
4
5
6
7
8
9
3.
4.
to store the selected values
to select the
function
Number is lit!
to confirm the choice
to adjust
the parameter
Number flashes!
yellow
blue
yellow
blue
Angle homing in speed closing*
Homing in speed
Opening force limitation
Speed limitation
Reset
Safety device in closing direction
Safety device for the swing area
x
x
off
3 °
Push-and-Go*
Opening time delay
motion
control
6 °
8 °
open-
position
hold-open
time
motion
control SS
11 °
13 °
16 °
19 °
21 °
24 °
open-
position SS
hold-open
time SS
0.2 s
0.4 s
1.2 s
1.6 s
2 s
2.4 s
2.8 s
3.2 s
3.6 s
Time control
Step control
Message door CLOSED
Message door OPEN
Lock locked currentless
Lock unlocked currentless
xxx
x
xx
x
xx
x
xx
xx x
xx x
x
xx
x
x
x
12 °
4 °
8 °
12 °
16 °
20 °
24 °
28 °
32 °
36 °
high
(final hit)
8
low.
off off
Factory
reset
See table in section 7.5, low energy applications
Factory settings
*All angular data is related to the drive shaft,
not to door leaf
SS = Key switch
7.4 Programming Table
T1132/33e
opening
speed
closing
speed
opening
speed SS
closing
speed SS
Safety device bodyguard
x
0.8 s
yellow
blue
+
=
Start programming mode
min.
min.
max.
max.