Figure18
1.Agitationcontrolvalve2.Pressuregauge
Note:Foragitationtowork,thepumpmustbeon
andtheenginemustberunningaboveanidle.Ifyou
stopthesprayerandneedagitationon,placetherange
selectorintheNeutralposition,settheparkingbrake,
presstheacceleratorpedaltotheoor,turnthepump
OnandturntheneutralenginespeedlockOn.
PressureGauge
Thepressuregaugeislocatedtotherightofthetank
(Figure18).Thisgaugeshowsthepressureoftheuid
inthesysteminpsiandkPa.Usethegaugetoadjustthe
by-passvalveswheneveryouchangenozzles.
Anti-siphonFillReceptacle
Tothefrontofthetankcoverisahosereceptaclewitha
threadedtting,a90degreebarbedtting,andashort
hosewhichyoucandirecttowardthetankopening.This
receptacleallowsyoutoconnectawaterhosetoitand
llthetankwithwaterwithoutcontaminatingthehose
withthechemicalsinthetank.
Important:Donotlengthenthehosetoallow
contactwiththetankuids.
21