ServicingtheFuses
Theelectricalsystemisprotectedbyfuses.Itrequiresno
maintenance;however,ifafuseblowscheckthecomponent
andcircuitforamalfunctionorshort.
Thefusesarelocatedonrightconsolenexttotheseat(Figure
59).
1.Toreplacethefuses,pulloutthefusetoremoveit.
2.Installanewfuse(Figure59).
Figure59
1.Optionalaccessory—15A
4.Main—25A
2.Charge—25A5.Console
3.PTO—10A
DriveSystem
Maintenance
CheckingtheSeatBelt
ServiceInterval:Beforeeachuseordaily
Inspecttheseatbeltforwear,cuts,andproperoperationof
theretractorandbuckle.Replacetheseatbeltifitisdamaged.
CheckingtheRollover
ProtectionSystem(ROPS)
Knobs
ServiceInterval:Beforeeachuseordaily
WARNING
Toavoidinjuryordeathfromrollover:keeptheroll
barinthefullyraisedlockedpositionandusethe
seatbelt.
Ensurethattheseatissecuredtothemachine.
Checkthatboththemountinghardwareandtheknobsarein
goodworkingcondition.Makesurethattheknobsarefully
engagedwiththeROPSintheraisedposition.Theupper
hoopoftherollbarmayneedtobepushedforwardorpulled
rearwardtogetbothknobsfullyengaged.