ElectricalSystem
Maintenance
ElectricalSystemSafety
Disconnectthebatterybeforerepairingthe
machine.Disconnectthenegativeterminalrst
andthepositivelast.Connectthepositiveterminal
rstandthenegativelast.
Chargethebatteryinanopen,well-ventilated
area,awayfromsparksandames.Unplugthe
chargerbeforeconnectingordisconnectingthe
battery.
Wearprotectiveclothinganduseinsulatedtools.
ReplacingtheFuses
Thefuseblockfortheelectricalsystemislocated
beneaththeoperator'sseat(Figure82).
g034159
Figure82
1.Openslot9.Openslot
2.Worklight
10.Openslot
3.Ignition
11.InfoCenter
4.TEClogic
12.Tankspray
5.TECpower13.Cruisecontrol
6.TECpower14.USBpower
7.Extrafuseslot
15.Boomandheadlight
8.Boomcontrol
16.TECpower
ServicingtheBattery
Alwayskeepthebatterycleanandfullycharged.Use
apapertoweltocleanthebatteryandbatterybox.If
thebatteryterminalsarecorroded,cleanthemwith
asolutionof4partswaterand1partbakingsoda.
Applyalightcoatingofgreasetothebatteryterminals
topreventcorrosion.
Voltage:12Vwith690coldcrankingampsat0°F
(-18°C)
RemovingtheBattery
1.Positionthesprayeronalevelsurface,engage
theparkingbrake,shutoffthespraypump,shut
offtheengine,andremovethekey.
2.Removethebatterycoveranddisconnectthe
negative(black)groundcablefromthebattery
post(Figure83).
g014029
Figure83
1.Batterycover3.Buckle
2.Strap
WARNING
Incorrectbatterycableroutingcould
damagethesprayerandcables,causing
sparks.Sparkscancausethebattery
gassestoexplode,resultinginpersonal
injury.
Alwaysdisconnectthenegative
(black)batterycablebefore
disconnectingthepositive(red)
cable.
Alwaysconnectthepositive(red)
batterycablebeforeconnectingthe
negative(black)cable.