e-STUDIO160/200/250 SCANNER 7 - 20 December 2002 TOSHIBA TEC
4. Remove the double-sided tape and remove the
ADF glass.
Note: For installing the ADF glass and original
glass and adjusting the tilt, refer to the Ser-
vice Handbook. (See Chapter 1.8)
Fig. 7-8-8
ADF glass
Original glass
043-2
[B] Original glass
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, open it.
2. Remove 2 screws and remove original glass
stay.
3. Remove 4 screws and remove original glass.
Fig. 7-8-7
Screw
Screw
Original glass stay
Original glass
043-1
25. Release the clamp and take out scanner as-
sembly.
Important: 1. After the replacement of the scan-
ner assembly, download firmware
for the scanner PWA. For details,
see chapter 5 of the Service Hand-
book.
2. Download the MAIN PWA firmware,
if necessary, after confirming the
version of it.
3. When the error message “F14” ap-
pears after replacing the scanner
assembly, refer to the Service
Handbook and perform (08-389).
Note: When mounting scanner assembly, be
careful not to damage the actuator.
Scanner assembly
Clamp
Fig. 7-8-6
042